| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | FUNGUS PROOF AND HERMETIC |
| FEATURES PROVIDED | ARC QUENCHING |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 12000.0 AC |
| OVERALL HEIGHT | 1.625 INCHES NOMINAL |
| OVERALL LENGTH | 2.312 INCHES NOMINAL |
| OVERALL WIDTH | 1.875 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 110.0 MILLIAMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.812 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| WINDING DC RESISTANCE RATING | 265.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 2 |
| TERMINAL TYPE AND QUANTITY | 3 TURRET ENERGIZING ELEMENT |
| TEST DATA DOCUMENT | 24930-G370097 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
| THREAD LENGTH | 0.437 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNS SINGLE MOUNTING FACILITY |
| TIME DELAY | 0.08 SECONDS MAXIMUM FIXED RELEASE TIME |