| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 342.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |
| DUTY TYPE | INTERMITTENT |
| ENVIRONMENTAL PROTECTION | WATERTIGHT |
| OVERALL LENGTH | 3.000 INCHES NOMINAL |
| OVERALL WIDTH | 1.170 INCHES NOMINAL |
| OVERALL HEIGHT | 2.890 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.136 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | POLARIZED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 00471 |
| DESIGN CONTROL REFERENCE | DK60GSC2 |