| DUTY TYPE | INTERMITTENT |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 DC |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.3 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| OVERALL HEIGHT | 3.500 INCHES NOMINAL |
| OVERALL LENGTH | 3.100 INCHES NOMINAL |
| OVERALL WIDTH | 2.700 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 12.6 AMPERES DC ALL WINDINGS |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1A |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 2 |
| TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
| TIME DELAY | 0.02 SECONDS MINIMUM AND 0.40 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |