NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 26.5 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 2 |
WINDING QUANTITY | 2 |
WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL FIRST WINDING |
| 514.0 OHMS NOMINAL SECOND WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 14.5 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.566 INCHES MAXIMUM |
OVERALL WIDTH | 1.130 INCHES MAXIMUM |
OVERALL HEIGHT | 1.887 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL SINGLE MOUNTING FACILITY |
FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND |
| LATCHING CONTACTS AND |
| POLARIZED |
SPECIAL FEATURES | GROUND TERMINAL COMMON TO BOTH COILS |