| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 26.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES DC RESISTIVE LOAD |
| ARC QUENCHING METHOD | INERT GAS |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 140.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 110.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 8.3 MILLIAMPERES DC SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.620 INCHES NOMINAL |
| OVERALL WIDTH | 1.620 INCHES NOMINAL |
| OVERALL HEIGHT | 3.130 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | POLARIZED |