| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC INDUCTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 425.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD ENERGIZING ELEMENT |
| 6 PIN CONTACTS |
| TIME DELAY | 0.06 SECONDS MINIMUM AND |
| 0.15 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.590 INCHES NOMINAL |
| OVERALL WIDTH | 1.000 INCHES NOMINAL |
| OVERALL HEIGHT | 2.500 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 02192 |
| DESIGN CONTROL REFERENCE | TDS6HX1 |