| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 2 |
| WINDING DC RESISTANCE RATING | 1.6 KILOHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 4.000 INCHES NOMINAL |
| OVERALL WIDTH | 3.870 INCHES NOMINAL |
| OVERALL HEIGHT | 3.250 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | CIRUCLAR SINGLE MOUNTING FACILITY |
| ANGLE BETWEEN ADJACENT MOUNTING FACILITIES | 90.0 DEGREES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.190 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |