| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND |
| 5.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 248.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES DC SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 2.120 INCHES NOMINAL |
| OVERALL WIDTH | 1.530 INCHES NOMINAL |
| OVERALL HEIGHT | 1.130 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 99687 |
| DESIGN CONTROL REFERENCE | 271-1449P1 |