| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.972 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| OVERALL HEIGHT | 0.970 INCHES NOMINAL |
| OVERALL LENGTH | 2.090 INCHES NOMINAL |
| OVERALL WIDTH | 0.970 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 4.2 MILLIAMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| WINDING DC RESISTANCE RATING | 1.25 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |