| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 29.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 1.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 430.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 56.0 MILLIAMPERES DC SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD ENERGIZING ELEMENT |
| 2 WIRE LEAD CONTACTS |
| TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE TIME |
| 0.008 SECONDS NOMINAL FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 1.405 INCHES NOMINAL |
| OVERALL WIDTH | 1.375 INCHES NOMINAL |
| OVERALL HEIGHT | 0.734 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |