| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | POLARIZED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 MILLIAMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 150.0 DC |
| OVERALL HEIGHT | 3.200 INCHES NOMINAL |
| OVERALL LENGTH | 1.840 INCHES NOMINAL |
| OVERALL WIDTH | 1.460 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 4C |
| WINDING DC RESISTANCE RATING | 8.000 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 12 WIRE HOOK CONTACTS |
| TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK ENERGIZING ELEMENT |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| TIME DELAY | 0.03 SECONDS NOMINAL FIXED OPERATE TIME |
| TIME DELAY | 0.03 SECONDS NOMINAL FIXED RELEASE TIME |