| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 250.0 MILLIAMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 20.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 1.650 INCHES NOMINAL |
| OVERALL WIDTH | 1.650 INCHES NOMINAL |
| OVERALL HEIGHT | 3.160 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |