| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.406 INCHES NOMINAL SECOND MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 29.0 DC |
| OVERALL HEIGHT | 1.688 INCHES MAXIMUM |
| OVERALL LENGTH | 1.813 INCHES NOMINAL |
| OVERALL WIDTH | 1.313 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | IN-LINE SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) FIRST MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE(S) SECOND MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SECOND MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES SILVER |
| PRECIOUS MATERIAL | SILVER |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING DC RESISTANCE RATING | 216.0 OHMS MINIMUM AND 264.0 OHMS MAXIMUM SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 20 BANANA PLUG ALL FUNCTIONS |
| THREAD CLASS | 2B SECOND MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SECOND MOUNTING FACILITY |