| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND |
| 30.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC AND |
| 7.0 AMPERES DC RESISTIVE LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
| TIME DELAY | 0.50 SECONDS MINIMUM AND |
| 5.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 4.520 INCHES MAXIMUM |
| OVERALL WIDTH | 3.250 INCHES MAXIMUM |
| OVERALL HEIGHT | 3.090 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.880 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 45.392 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |