| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | NITROGEN |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC AND 50.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 18.0 VOLTS AC 25 DEG CELSIUS AND 29.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 3.150 INCHES NOMINAL |
| OVERALL LENGTH | 3.000 INCHES NOMINAL |
| OVERALL WIDTH | 1.800 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 12 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IRREGULARLY SPACED SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 300.0 MILLIAMPERES DC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 96.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |