| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 2.039 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 1.593 INCHES MAXIMUM |
| OVERALL LENGTH | 1.343 INCHES MAXIMUM |
| OVERALL WIDTH | 0.953 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 9 PIN ALL FUNCTIONS |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |