| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 2.5 KILOHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 36.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 6.5 MILLIAMPERES DC SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 1.380 INCHES NOMINAL |
| OVERALL WIDTH | 0.740 INCHES NOMINAL |
| OVERALL HEIGHT | 0.950 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.099 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |