PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C AND |
| 1A1B1C |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 1.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 2.62 KILOHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 15 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | DUSTPROOF |
OVERALL LENGTH | 3.938 INCHES NOMINAL |
OVERALL WIDTH | 0.875 INCHES NOMINAL |
OVERALL HEIGHT | 1.797 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |