MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 27.5 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND |
| 3.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 427.5 OHMS MINIMUM AND |
| 522.5 OHMS MAXIMUM SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
NOMINAL OPERATING CURRENT RATING AND TYPE | 242.0 MILLIAMPERES AC SINGLE WINDING |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.620 INCHES MAXIMUM |
OVERALL WIDTH | 1.430 INCHES MAXIMUM |
OVERALL HEIGHT | 2.060 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.933 INCHES MINIMUM AND |
| 0.943 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
SPECIAL FEATURES | 2ND C TO C DISTANCE BETWEEN MTG STUDS 1.187 IN. PLUS 0.005 |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 56232 |
DESIGN CONTROL REFERENCE | 827115J |