| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.688 INCHES NOMINAL SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES NOMINAL FIRST MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 13.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| OVERALL HEIGHT | 3.370 INCHES NOMINAL |
| OVERALL LENGTH | 3.000 INCHES NOMINAL |
| OVERALL WIDTH | 2.620 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD(S) SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD(S) FIRST MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE FIRST MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SECOND MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 4.0 AMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.138 INCHES SECOND MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.250 INCHES FIRST MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
| THREAD CLASS | 2A SECOND MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 20 FIRST MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) FIRST MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SECOND MOUNTING FACILITY |