| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 3.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 400.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| TIME DELAY | 2.55 MINUTES NOMINAL FIXED OPERATE TIME |
| 0.10 SECONDS MAXIMUM FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 2.156 INCHES MAXIMUM |
| OVERALL WIDTH | 1.375 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.375 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | POLARIZED |