| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.844 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 2 |
| CUBIC MEASURE | 7.365 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | LATCHING CONTACTS |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.5 AMPERES AC AND 1.5 AMPERES DC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 800.0 MILLIAMPERES AC AND 800.0 MILLIAMPERES DC LAMP LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 2.156 INCHES NOMINAL |
| OVERALL LENGTH | 2.187 INCHES MAXIMUM |
| OVERALL WIDTH | 1.562 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES GOLD |
| PRECIOUS MATERIAL | GOLD |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| SPECIFICATION/STANDARD DATA | 96906-MS25463 GOVERNMENT STANDARD |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 2 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 22 PIN ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE TIME |