| DUTY TYPE | CONTINUOUS |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 DC |
| COIL QUANTITY | 1 |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 250.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 500.0 AC AND 400.0 DC |
| OVERALL HEIGHT | 3.938 INCHES NOMINAL |
| OVERALL LENGTH | 4.438 INCHES NOMINAL |
| OVERALL WIDTH | 2.375 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 CLINCH NUT SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 80.0 MILLIAMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 48.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| WINDING DC RESISTANCE RATING | 550.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 9 PIN ALL FUNCTIONS |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |