| DUTY TYPE | CONTINUOUS |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.938 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| OVERALL HEIGHT | 2.562 INCHES NOMINAL |
| OVERALL LENGTH | 3.375 INCHES NOMINAL |
| OVERALL WIDTH | 2.062 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 0.22 AMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY AND 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 22.0 VOLTS DC 25 DEG CELSIUS AND 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| WINDING DC RESISTANCE RATING | 125.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |