| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | NITROGEN |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES DC RESISTIVE LOAD |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 1.870 INCHES MAXIMUM |
| OVERALL LENGTH | 1.750 INCHES NOMINAL |
| OVERALL WIDTH | 1.680 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 0.01 AMPERES DC SINGLE WINDING |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 8000.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |