| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.354 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC INDUCTIVE LOAD |
| OVERALL HEIGHT | 0.938 INCHES MAXIMUM |
| OVERALL LENGTH | 1.188 INCHES NOMINAL |
| OVERALL WIDTH | 0.734 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 8.5 MILLIAMPERES DC SINGLE WINDING |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.109 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 1.0 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TIME DELAY | 0.008 SECONDS NOMINAL FIXED RELEASE TIME |
| TIME DELAY | 0.0150 SECONDS NOMINAL FIXED OPERATE TIME |