| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC INDUCTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| TIME DELAY | 2.00 SECONDS MINIMUM AND |
| 1.00 MINUTES MAXIMUM ADJUSTABLE OPERATE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| OVERALL WIDTH | 2.900 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.300 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 12 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | CIRUCLAR SINGLE MOUNTING FACILITY |
| ANGLE BETWEEN ADJACENT MOUNTING FACILITIES | 36.0 DEGREES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.166 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | POLARIZED |