| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 2 |
| CUBIC MEASURE | 11.886 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 2.310 INCHES MAXIMUM |
| OVERALL LENGTH | 3.840 INCHES MAXIMUM |
| OVERALL WIDTH | 1.340 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 1.5 AMPERES DC ALL WINDINGS |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1C |
| PRECIOUS MATERIAL AND LOCATION | CONTACTS PALLADIUM |
| PRECIOUS MATERIAL | PALLADIUM |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING DC RESISTANCE RATING | 225.0 OHMS NOMINAL ALL WINDINGS |
| WINDING QUANTITY | 2 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD ENERGIZING ELEMENT |
| TERMINAL TYPE AND QUANTITY | 18 PIN CONTACTS |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| TIME DELAY | 0.002 SECONDS NOMINAL FIXED RELEASE TIME |
| TIME DELAY | 0.012 SECONDS NOMINAL FIXED OPERATE TIME |