| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.200 INCHES NOMINAL SECOND MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 1.153 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 32.0 AC AND 32.0 DC |
| OVERALL HEIGHT | 1.281 INCHES MAXIMUM |
| OVERALL LENGTH | 2.915 INCHES MAXIMUM |
| OVERALL WIDTH | 0.410 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | IN-LINE SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) FIRST MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) SECOND MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 25.6 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL SECOND MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 4.5 KILOHMS MINIMUM AND 5.0 KILOHMS MAXIMUM SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |