| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.690 INCHES MINIMUM AND 0.710 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 0.851 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| OVERALL HEIGHT | 1.041 INCHES MAXIMUM |
| OVERALL LENGTH | 1.010 INCHES MAXIMUM |
| OVERALL WIDTH | 0.810 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 6.5 MILLIAMPERES DC SINGLE WINDING |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 73.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| SPECIFICATION/STANDARD DATA | 00724-47-00123-001 MANUFACTURERS SPECIFICATION CONTROL |
| WINDING DC RESISTANCE RATING | 9.0 KILOHMS MINIMUM AND 13.5 KILOHMS MAXIMUM SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD LENGTH | 0.344 INCHES MINIMUM AND 0.375 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| TIME DELAY | 0.005 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 0.006 SECONDS MAXIMUM FIXED OPERATE TIME |