| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 TWO CIRCUIT, BOTH POSITIONS MAINTAINED |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 32.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 2 |
| WINDING DC RESISTANCE RATING | 1.6 KILOHMS NOMINAL ALL WINDINGS |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 3.562 INCHES NOMINAL |
| OVERALL WIDTH | 3.062 INCHES NOMINAL |
| OVERALL HEIGHT | 4.875 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | LATCHING CONTACTS |