| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.495 INCHES MINIMUM AND 0.505 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 2.256 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 1.750 INCHES MINIMUM AND 1.781 INCHES MAXIMUM |
| OVERALL LENGTH | 1.391 INCHES MINIMUM AND 1.422 INCHES MAXIMUM |
| OVERALL WIDTH | 0.859 INCHES MINIMUM AND 0.891 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1C AND 2A |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING DC RESISTANCE RATING | 365.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 9 WIRE HOOK ALL FUNCTIONS |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
| TIME DELAY | 0.01 SECONDS NOMINAL FIXED RELEASE TIME |
| TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE TIME |