| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.073 INCHES MINIMUM AND 1.083 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 0.468 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC INDUCTIVE LOAD |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 114.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 0.890 INCHES MINIMUM AND 0.900 INCHES MAXIMUM |
| OVERALL LENGTH | 1.320 INCHES MINIMUM AND 1.330 INCHES MAXIMUM |
| OVERALL WIDTH | 0.390 INCHES MINIMUM AND 0.400 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) SECOND MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) FIRST MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE FIRST MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 6.3 MILLIAMPERES DC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.115 INCHES MINIMUM AND 0.125 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 8.0 KILOHMS MINIMUM AND 12.0 KILOHMS MAXIMUM SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| TIME DELAY | 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE TIME |