5305-01-106-1122 SCREW,CLOSE TOLERANCE Index 5970-01-106-1124 INSULATOR,PLATE

National Stock Number:
5940-01-106-1123

Federal Supply Class:
5940

National Item Identification Number:
011061123

Description:
TERMINAL,STUD

Detail:
A terminal, generally postlike, having an axial portion of its body designed for projecting through or into a panel, or the like, for mounting. Requires the use of tool(s) for attachment of wire. The conductor connection may be insulated from the mounting. Excludes TERMINAL, FEEDTHRU. See also TERMINAL, QUICK DISCONNECT and TERMINAL SET, QUICK DISCONNECT.


Manufacturer Information:
2762-14-117117ELECTRONIC MOLDING CORP
2762-91-117117ELECTRONIC MOLDING CORP


Techincal Specification:
ELECTRICAL INSULATION FEATURESTANDOFF INSULATION
BASIC SHAPE STYLENONTUBULAR, HEX
CONDUCTOR ACCOMMODATION TYPEPIN SINGLE END
IDENTIFICATION CODE COLORBROWN
LARGEST DIAMETER0.078 INCHES SINGLE END
MATERIAL DOCUMENT AND CLASSIFICATIONMIL-M-14,TYPE SDG-F MIL SPEC SINGLE MATERIAL RESPONSE INSULATION
MATERIAL DOCUMENT AND CLASSIFICATIONQQ-B-626,COMP 22 FED SPEC SINGLE MATERIAL RESPONSE OVERALL EXCEPT INSULATION
MATERIALCOPPER ALLOY OVERALL EXCEPT INSULATION
MATERIALPLASTIC DIALLYL PHTHALATE INSULATION
MOUNTING METHOD STYLETAPPED HOLE
MOUNTING THREAD DIAMETER0.086 INCHES
MOUNTING THREAD SERIESUNIFIED NATIONAL COARSE (UNC)
OVERALL HEIGHT0.625 INCHES
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONQQ-A-673,TYPE 2 FED SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION FIRST LAYER
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONMIL-T-10727,TYPE I MIL SPEC SINGLE TREATMENT RESPONSE CONDUCTOR ACCOMMODATION SECOND LAYER
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONQQ-P-416 FED SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY FIRST LAYER
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONQQ-P-416 FED SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY SECOND LAYER
SURFACE TREATMENTCADMIUM MOUNTING FACILITY FIRST LAYER
SURFACE TREATMENTCHROMATE MOUNTING FACILITY SECOND LAYER
SURFACE TREATMENTCOPPER CONDUCTOR ACCOMMODATION FIRST LAYER
SURFACE TREATMENTTIN CONDUCTOR ACCOMMODATION SECOND LAYER
TERMINAL LENGTH0.250 INCHES
THREAD LENGTH0.156 INCHES
WIDTH ACROSS FLATS0.250 INCHES