| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 20,0 MILLIMETERS NOMINAL |
| BODY HEIGHT | 125,0 MILLIMETERS NOMINAL |
| BODY LENGTH | 33,5 MILLIMETERS NOMINAL |
| BODY WIDTH | 33,0 MILLIMETERS NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +10,00 TO 160,00 ACTUATION POINT BAR |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW |
| CONTACT LOAD CURRENT RATING | 1,6 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 100,0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 9,0 DIFFERENTIAL POINT MINIMUM BAR AND 18,0 DIFFERENTIAL POINT MAXIMUM BAR |
| CONTACT VOLTAGE RATING IN VOLTS | 220,0 DC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 380,0 AC AT SEA LEVEL FIRST VOLTAGE |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT AND TAMPER PROOF CAP |
| III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SCHUTZART IP54 |
| III STYLE DESIGNATOR | RECTANGULAR |
| PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
| PRESSURE SWITCH TYPE | ABSOLUTE |
| PROOF PRESSURE | 250,0 BAR |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| MOUNTING METHOD | UNTHREADED HOLE |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING TEMP RATING | -5,0 DEG CELSIUS MINIMUM AND 90,0 DEG CELSIUS MAXIMUM |
| OVERALL HEIGHT | 125,0 MILLIMETERS NOMINAL |
| OVERALL LENGTH | 80,0 MILLIMETERS NOMINAL |
| OVERALL WIDTH | 33,0 MILLIMETERS NOMINAL |
| SPECIAL FEATURES | KABELENFUEHRUNG 1XPG13,5 |
| TERMINAL TYPE | SCREW |
| THREAD SERIES DESIGNATOR | WHITWORTH PIPE, DIN 259 SINGLE PRESSURE CONNECTION |
| UNTHREADED MOUNTING HOLE DIAMETER | 5,3 MILLIMETERS NOMINAL |