CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL FIRST VOLTAGE |
OPERATING TEMP RATING | -54.0 DEG CELSIUS MINIMUM AND |
| 121.0 DEG CELSIUS MAXIMUM |
PROOF PRESSURE | 100.0 POUNDS PER SQUARE INCH |
SPECIAL FEATURES | OPERATING TEMPERATURE: -54C TO 121C FROM -1000 TO 30,000 FEET ALTITUDE, NONOPERATING TEMPERATURE: SPECIFIED PERFORMANCE SHALL BE MAINTAINED FOLLOWING LONG PERIODS OF EXPOSURE TO AMBIENT TEMPERATURES BETWEEN -65C TO 149C AND FROM -1000 TO 50,000 FEET ALTITUDE |
SPECIAL TEST FEATURES | RELIABILITY: THE SWITCH SHALL BE DESIGNED AND CONSTRUCTED TO OPERATE A MINIMUM OF 100,000 CYCLES |
SENSING ELEMENT BURST PRESSURE | 250.0 POUNDS PER SQUARE INCH |
SUPPLEMENTARY FEATURES | THE SWITCH SHALL PROVIDE SPECIFIED PERFORMANCE WHEN EXCITED BY AN EXTERNAL VOLTAGE OF 16 TO 30V DC, THE SWITCH SHALL NOT BE DAMAGED AND SHALL BE CAPABLE OF RETURNING TO SPECIFIED PERFORMANCE AFTER PROLONGED EXPOSURE TO VOLTAGES AS HIGH AS 32V DC (28 V DC NOMINAL) IAW MIL-STD-704 |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 97499 |
MFR SOURCE CONTROLLING REFERENCE | 901-375-911-105 |