| CONTACT LOAD CURRENT RATING | 150.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| CONTACT LOAD CURRENT RATING | 50.0 MILLIAMPERES INDUCTIVE LOAD AND 100.0 MILLIAMPERES LAMP LOAD AND 200.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
| DETENT ROTATIONAL TORQUE RANGE | +0.500 TO 1.500 INCH-POUNDS SINGLE ACTUATOR |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF AND MOISTURE RESISTANT |
| INDIVIDUAL SECTION QUANTITY | 1 |
| OVERALL DIAMETER | 0.547 INCHES MINIMUM AND 0.577 INCHES MAXIMUM |
| OVERALL LENGTH | 1.202 INCHES MINIMUM AND 1.642 INCHES MAXIMUM |
| OPERATING TEMP RANGE | -65.0 TO 85.0 CELSIUS |
| SPECIFICATION/STANDARD DATA | 81349-MIL-S-3786/35 GOVERNMENT SPECIFICATION |
| STYLE DESIGNATOR | SNAP OR LINE |
| SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| TERMINAL TYPE | TAB, SOLDER LUG AND TURRET |
| TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |