| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTMENT RANGE | -65.00 TO 300.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT TONGUE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT STIMULUS RATING | 45.00 ACTUATION POINT NOMINAL DEGREES CELSIUS |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| FLANGE OVERALL WIDTH | 1.438 INCHES NOMINAL |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.070 INCHES MINIMUM AND 1.090 INCHES MAXIMUM |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.930 INCHES MINIMUM AND 0.950 INCHES MAXIMUM |
| OVERALL LENGTH | 3.062 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS |
| MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE(S) |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.530 INCHES MINIMUM AND 0.550 INCHES MAXIMUM |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.224 INCHES MINIMUM AND 0.244 INCHES MAXIMUM |
| STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
| TEMP SENSING ELEMENT TYPE | EXPANDING SHELL |
| TERMINAL TYPE | TAB, SOLDER LUG |