| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT HEX NUT |
| CONTACT ADJUSTMENT RANGE | +30.00 TO 600.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE |
| CONTACT LOAD CURRENT RATING | 0.25 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CONTACT LOAD CURRENT RATING | 0.5 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.156 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| OVERALL HEIGHT | 7.500 INCHES NOMINAL |
| OVERALL LENGTH | 3.719 INCHES NOMINAL |
| OVERALL WIDTH | 4.062 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| MOUNTING METHOD | FLANGE AND SLOT |
| MOUNTING SLOT WIDTH | 0.344 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PRESSURE SWITCH TYPE | GAGE |
| SPECIAL FEATURES | TWO INDEPENDENTLY ADJUSTABLE SET POINTS |
| STYLE DESIGNATOR | RECTANGULAR |
| TERMINAL TYPE | SCREW |