| BODY LENGTH | 2.063 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 20.00 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND 27.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND MOISTURE PROOF |
| III STYLE DESIGNATOR | CYLINDRICAL |
| PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| PRESSURE SWITCH TYPE | GAGE |
| PROPRIETARY CHARACTERISTICS | PACS |
| PROOF PRESSURE | 500.00 POUNDS PER SQUARE INCH |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING METHOD | INPUT PORT |
| NOMINAL THREAD SIZE | 0.125 INCHES SINGLE PRESSURE CONNECTION |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| OUTSIDE DIAMETER | 0.125 INCHES NOMINAL SINGLE CONNECTION |
| OVERALL DIAMETER | 2.000 INCHES NOMINAL |
| OVERALL LENGTH | 3.000 INCHES NOMINAL |
| SENSING ELEMENT BURST PRESSURE | 750.00 POUNDS PER SQUARE INCH |
| SPECIAL FEATURES | FIRST POLE OPENS AT MINIMUM CONTACT STIMULUS RATING SECOND POLE OPENS AT MAXIMUM CONTACT STIMULUS RATING |
| WIDTH ACROSS FLATS | 0.562 INCHES NOMINAL |
| TERMINAL TYPE | THREADED STUD |
| THREAD SERIES DESIGNATOR | NPTF SINGLE PRESSURE CONNECTION |