| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 3.00 ACTUATION POINT NOMINAL GALLONS PER MINUTE AND 1.75 DEACTUATION POINT NOMINAL GALLONS PER MINUTE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| OPERATING TEMP RATING | 220.0 FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING METHOD | LINE AND THREADED HOLE(S) |
| NOMINAL THREAD SIZE | 1.000 INCHES ALL THREADED HOLE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| TERMINAL TYPE | WIRE LEAD |
| THREAD SERIES DESIGNATOR | NPT ALL THREADED HOLE |