| CONTACT ADJUSTMENT RANGE | -20.00 TO 500.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND SALT SPRAY RESISTANT |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | BRACKET(S) AND UNTHREADED HOLE(S) |
| PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
| PRECIOUS MATERIAL | SILVER |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | WIRE LEAD |