| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET OR DEACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | +100.00 TO 1850.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW |
| CONTACT LOAD CURRENT RATING | 1.5 AMPERES RESISTIVE LOAD AND 0.5 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| III OVERALL LENGTH | 4.060 INCHES NOMINAL |
| III STYLE DESIGNATOR | CYLINDRICAL |
| PROPRIETARY CHARACTERISTICS | PACS |
| MEDIA FOR WHICH DESIGNED | GAS |
| MOUNTING METHOD | THREADED BUSHING |
| NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| OPERATING TEMP RATING | 2000.0 DEG FAHRENHEIT MAXIMUM |
| WIDTH ACROSS FLATS | 0.870 INCHES NOMINAL |
| TEMP SENSING ELEMENT TYPE | EXPANDING ROD |
| TERMINAL TYPE | TAB W/SCREW |
| THREAD CLASS | 3A SINGLE THREADED BUSHING |
| THREAD DIRECTION | RIGHT-HAND SINGLE THREADED BUSHING |
| THREAD LENGTH | 0.437 INCHES NOMINAL SINGLE THREADED BUSHING |
| THREAD QUANTITY PER INCH | 20 SINGLE THREADED BUSHING |
| THREAD SERIES DESIGNATOR | UNF SINGLE THREADED BUSHING |