| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.375 INCHES NOMINAL |
| BODY LENGTH | 4.125 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 0.4 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 0.5 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 60.0 MILLIAMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CONTACT LOAD CURRENT RATING | 80.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT STIMULUS RATING | 0.80 ACTUATION POINT MAXIMUM GALLONS PER MINUTE AND 0.60 DEACTUATION POINT MINIMUM GALLONS PER MINUTE |
| CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 240.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL THIRD VOLTAGE |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| PROPRIETARY CHARACTERISTICS | PACS |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OVERALL HEIGHT | 1.000 INCHES NOMINAL |
| OVERALL WIDTH | 1.750 INCHES NOMINAL |
| TERMINAL TYPE | WIRE LEAD |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |