5955-01-191-2896 CRYSTAL UNIT,QUARTZ Index 5915-01-191-2898 FILTER,BAND PASS

National Stock Number:
5930-01-191-2897

Federal Supply Class:
5930

National Item Identification Number:
011912897

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
222-10NH1-222313919278DETROIT SWITCH INC
222-3139 NH119278DETROIT SWITCH INC


Techincal Specification:
BODY HEIGHT2.500 INCHES NOMINAL2.500 INCHES NOMINAL
CONTACT ACTION STIMULUSINCREASEINCREASE
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT LOAD CURRENT RATING8.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
CONTACT LOAD CURRENT RATING9.6 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE
CONTACT LOAD CURRENT RATING16.0 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE
CONTACT LOAD CURRENT RATING2.5 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE
CONTACT LOAD CURRENT RATING3.2 AMPERES INDUCTIVE LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING4.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING4.8 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FOURTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 DC AT SEA LEVEL EIGHTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 AC AT SEA LEVEL THIRD VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 DC AT SEA LEVEL SEVENTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS440.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS440.0 DC AT SEA LEVEL SIXTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 DC AT SEA LEVEL FIFTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FIRST VOLTAGE
FEATURES PROVIDEDELECTRICAL ACCESS PORTELECTRICAL ACCESS PORT
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
FREQUENCY IN HERTZ60.0 SECOND VOLTAGE
FREQUENCY IN HERTZ60.0 FOURTH VOLTAGE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONDUSTPROOF AND DUSTPROOF AND WATERTIGHTWATERTIGHT
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL2.406 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL3.281 INCHES NOMINAL
OVERALL LENGTH4.875 INCHES NOMINAL4.875 INCHES NOMINAL
OVERALL WIDTH2.875 INCHES NOMINAL2.875 INCHES NOMINAL
MOUNTING FACILITY PATTERNTWO POSITION IN-LINETWO POSITION IN-LINE
MOUNTING METHODBRACKET(S) AND BRACKET(S) AND UNTHREADED HOLE(S)UNTHREADED HOLE(S)
OVERALL HEIGHT5.687 INCHES NOMINAL5.687 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL0.656 INCHES NOMINAL
TEMP SENSING ELEMENT TYPEBULBBULB
TERMINAL TYPESCREWSCREW
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL0.281 INCHES NOMINAL