6150-01-189-0498 WIRING HARNESS Index 5930-01-189-0502 SWITCH,THERMOSTATIC

National Stock Number:
5930-01-189-0499

Federal Supply Class:
5930

National Item Identification Number:
011890499

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
222-32NL-222237219278DETROIT SWITCH INC
NF9-2012888234UNITED ELECTRIC CONTROLS COMPANY


Techincal Specification:
BODY HEIGHT2.750 INCHES NOMINAL
BULB DIAMETER0.688 INCHES NOMINAL
BULB LENGTH3.625 INCHES NOMINAL
CAPILLARY TUBE LENGTH120.0 INCHES NOMINAL
CONTACT ACTION STIMULUSDECREASE
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+150.00 TO 225.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE
CONTACT LOAD CURRENT RATING16.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD EIGHTH VOLTAGE
CONTACT LOAD CURRENT RATING2.5 AMPERES RESISTIVE LOAD SEVENTH VOLTAGE
CONTACT LOAD CURRENT RATING3.4 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING4.2 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CONTACT LOAD CURRENT RATING4.8 AMPERES RESISTIVE LOAD SIXTH VOLTAGE
CONTACT LOAD CURRENT RATING8.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING9.6 AMPERES RESISTIVE LOAD FIFTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 DC AT SEA LEVEL FIFTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 DC AT SEA LEVEL SIXTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS440.0 AC AT SEA LEVEL THIRD VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS440.0 DC AT SEA LEVEL SEVENTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 DC AT SEA LEVEL EIGHTH VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FOURTH VOLTAGE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.406 INCHES NOMINAL
FEATURES PROVIDEDCAPILLARY TUBE END SEAL CONNECTION
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
OVERALL HEIGHT5.406 INCHES NOMINAL
OVERALL LENGTH5.188 INCHES NOMINAL
OVERALL WIDTH2.812 INCHES NOMINAL
MEDIA FOR WHICH DESIGNEDGAS OR LIQUID
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE
MOUNTING METHODBRACKET(S) AND UNTHREADED HOLE(S)
NONPILE-UP CONTACT ARRANGEMENT2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES SILVER
PRECIOUS MATERIALSILVER
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
TERMINAL TYPESCREW


Click here to Register for Free 30-day Trial