| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.250 INCHES NOMINAL |
| BODY HEIGHT | 2.125 INCHES NOMINAL |
| BODY WIDTH | 2.188 INCHES NOMINAL |
| BULB DIAMETER | 0.312 INCHES NOMINAL |
| BULB LENGTH | 3.625 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 24.0 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE, MANUAL RESET |
| CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT STIMULUS RATING | 450.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
| FEATURES PROVIDED | MANUAL RESET BUTTON |
| III OVERALL LENGTH | 1.500 INCHES NOMINAL |
| PROPRIETARY CHARACTERISTICS | PACS |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| OVERALL WIDTH | 2.438 INCHES NOMINAL |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |