| BODY DIAMETER | 0.640 INCHES MAXIMUM |
| BODY HEIGHT | 0.260 INCHES MINIMUM AND 0.325 INCHES MAXIMUM |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE |
| CONTACT STIMULUS RATING | 175.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 150.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT ALTITUDE THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES NOMINAL |
| FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
| OVERALL HEIGHT | 0.503 INCHES MINIMUM AND 0.568 INCHES MAXIMUM |
| OVERALL LENGTH | 1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| MOUNTING METHOD | SLOT |
| MOUNTING SLOT WIDTH | 0.140 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL |
| STYLE DESIGNATOR | DISC W/FLANGE |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TAB, SOLDER LUG |