| BODY DIAMETER | 1.440 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT HEX NUT AND EXTERNAL ACTUATION POINT HEX NUT |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +13.00 TO 80.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +11.60 TO 72.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 3.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND 250.0 MILLIAMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE AND ELECTRICAL ACCESS PORT |
| FREQUENCY IN HERTZ | 50.0 AND 60.0 FIRST VOLTAGE |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| OVERALL DIAMETER | 1.870 INCHES NOMINAL |
| OVERALL LENGTH | 4.000 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING METHOD | INPUT PORT |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PRESSURE SWITCH TYPE | GAGE |
| PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| PROOF PRESSURE | 1000.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | WIRE LEAD |
| THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
| THREAD SERIES DESIGNATOR | PTF-SAE SHORT SINGLE PRESSURE CONNECTION |