| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CONTACT STIMULUS RATING | 30.00 ACTUATION POINT NOMINAL INCHES OF WATER AND 26.00 DEACTUATION POINT NOMINAL INCHES OF WATER AND 4.00 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
| CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.300 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.300 INCHES NOMINAL |
| OPERATING TEMP RATING | -54.0 CELSIUS MINIMUM AND 71.0 CELSIUS MAXIMUM |
| OVERALL DIAMETER | 0.500 INCHES NOMINAL |
| OVERALL LENGTH | 4.000 INCHES MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| MOUNTING FACILITY PATTERN | FOUR POSITION DIAMOND |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE(S) |
| NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.150 INCHES NOMINAL |
| SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.150 INCHES NOMINAL |
| PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| PROOF PRESSURE | 9.00 POUNDS PER SQUARE INCH |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES MINIMUM AND 0.215 INCHES MAXIMUM |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| THREAD CLASS | 3B ALL PRESSURE CONNECTION |
| THREAD QUANTITY PER INCH | 20 ALL PRESSURE CONNECTION |
| THREAD SERIES DESIGNATOR | UNF ALL PRESSURE CONNECTION |